Estimate Annual Data Loss Risk for a Dual-Parity Flash Shelf
Last updated: November 29, 2026
Quick Overview
An array has 24 flash modules protected by dual parity, each module has a 1 percent annual failure rate, and a rebuild after a failure takes 4 hours. Estimate the probability per year of losing data, and explain how rebuild time, parity level and correlated failures change the answer.
Pure Storage
November 29, 20260
0
0 solved
An array has 24 flash modules protected by dual parity, each module has a 1 percent annual failure rate, and a rebuild after a failure takes 4 hours. Estimate the probability per year of losing data, and explain how rebuild time, parity level and correlated failures change the answer.
Pure markets very high availability, and Pure1 analytics teams model module failure rates across the installed base to set sparing and proactive replacement policy. The interviewer checks that you can set up a defensible reliability model quickly, compute it, and then say where independence assumptions break.
What the Interviewer Expects
- Models failures as a Poisson process with a per-module hourly rate
- Recognizes that data loss needs parity+1 overlapping failures inside one rebuild window
- Computes the binomial tail for further failures among survivors
- Shows how risk scales with rebuild time (roughly quadratically for dual parity)
- Calls out correlated failures (same batch, firmware, power) as the dominant real risk
- Mentions latent sector errors found during rebuild
Key Topics to Cover
How to Approach This
- Define your hypotheses (H0 and H1) clearly before performing any test.
- Calculate required sample size BEFORE running an experiment, using power analysis.
- Remember the Central Limit Theorem: sample means become approximately normal with large n.
- Watch for Simpson's paradox. Always segment data by key dimensions.
- Distinguish between statistical significance and practical significance.
Possible Follow-up Questions
- How would you estimate the AFR itself from fleet telemetry with modules of different ages?
- How does the answer change if a failing module is drained proactively before it dies?
- How would you incorporate a bathtub-shaped hazard rather than a constant rate?
- At what fleet size does a one-in-a-billion per-array risk become a real yearly event?
Sharpen Your Skills on Codemia
Practice similar problems with our interactive workspace, get AI feedback, and track your progress.
Browse Statistics QuestionsSample Answer
Clarify
Assume independent failures at a constant rate, n = 24 modules, AFR = 0.01, rebuild window T = 4 hours, and dual parity, so data is lost if 2 more modules fail while the first is rebuilding. I ignore ...
Approach
The hourly rate per module is . Expected first failures per year are . Given a failure, each of the 23 survivors fails within the window with ...